Electric Actuator

Model NO.: EA-0000194
Torque: 20~2000nm
Protection Class: IP67
Type: on/off, Regulating
Control Signal: 4~20mA
Trademark: Grat
Transport Package: Carton/Wooden Box
Specification: CE, TUV, ISO
Origin: Wuhan, Hubei, China
HS Code: 8537109090
Model NO.: EA-0000194
Torque: 20~2000nm
Protection Class: IP67
Type: on/off, Regulating
Control Signal: 4~20mA
Trademark: Grat
Transport Package: Carton/Wooden Box
Specification: CE, TUV, ISO
Origin: Wuhan, Hubei, China
HS Code: 8537109090
                               Electric actuator

Product Description
Electric Actuator
 

1.Technical parameters

            Type 20 50 100 200 400 600 1000 1500 2000
 Characteristics
Output torque 20NM 50NM 100NM 200NM 400NM 600NM 1000NM 1500NM 2000NM
Action time(S) 10/20 4/10
20/60
4/7
15/30/60
6/15
30/60
6/15
30/60
45 15/30 48 60/75
Gyration angle 0-90°
0-360°
0-90°
0-360°
0-90°
0-360°
0-90° 0-90° 0-90° 0-90° 0-90° 0-90°
Motor power(W) AC220V 6 10 25 40 90 90 120 140 140
AC380V   ------- 6 15 30 40 40 90 100  --------
DC24V 8 13 25 35 70 70 --------- --------- ----------
Rated current(A) AC220V 0.16 0.16 0.32 0.35 0.54 0.64 0.96 0.98 1.03
AC380V --------- 0.07 0.1 0.15 0.29 0.29 0.45 0.46  ---------
DC24V 0.7 1.28 2.03 3.57 5.13 3.04 --------- --------  --------
Weight(Kg) 1.2 2.5 3.5 8 8.5 9 17 18 20
Power   AC 220V±10% 50HZ/60HZ,  AC 380V±10% 50HZ/60HZ, DC24V
Insulation resistance   100MΩ/500VDC 
Anti-pressure level   1500VAC 1Min
Protection level   IP67(It is no leakage in water about 20 meters deep)
Limited component   Power-driven: Fully open and close, limit switch.
  Manual: Mechanical stopper.
Protector   Overheat protector(self-recovery)
Installation position   Any direction from 0 to 360 degree
Electrical connection   M20*1.5 Waterproof cable connection, power wire, signal wire
Ambient Temp.   -30ºC--60ºC
 

2.Installation Diagram

Electric Actuator

3.Control Diagram
Electric Actuator

Model Circuit Model Circuit
S ON/OFF,no output signal CPT ON/OFF,output 4~20mA signal
MS ON/OFF,output passive contact signal PCU Regulation,output 4~20mA signal
PIU ON/OFF,output 0~1000Ω signal G ON/OFF,output passive contact signal
SP ON/OFF,middle position control H ON/OFF,output passive contact signal

 

Packing&Shipping
1.Packing: inner with bubble wrap,outer with cardboard box and wooden case.
2.Transportation:by sea,by air,by train.

Our Services
1.Professional consultation
2.24 hours response after sale.
3.One year warranty.
4.Safe packing for shipment.
5.Welcome sample order.

 

                               Electric actuator

Product Description
Electric Actuator
 

1.Technical parameters

            Type 20 50 100 200 400 600 1000 1500 2000
 Characteristics
Output torque 20NM 50NM 100NM 200NM 400NM 600NM 1000NM 1500NM 2000NM
Action time(S) 10/20 4/10
20/60
4/7
15/30/60
6/15
30/60
6/15
30/60
45 15/30 48 60/75
Gyration angle 0-90°
0-360°
0-90°
0-360°
0-90°
0-360°
0-90° 0-90° 0-90° 0-90° 0-90° 0-90°
Motor power(W) AC220V 6 10 25 40 90 90 120 140 140
AC380V   ------- 6 15 30 40 40 90 100  --------
DC24V 8 13 25 35 70 70 --------- --------- ----------
Rated current(A) AC220V 0.16 0.16 0.32 0.35 0.54 0.64 0.96 0.98 1.03
AC380V --------- 0.07 0.1 0.15 0.29 0.29 0.45 0.46  ---------
DC24V 0.7 1.28 2.03 3.57 5.13 3.04 --------- --------  --------
Weight(Kg) 1.2 2.5 3.5 8 8.5 9 17 18 20
Power   AC 220V±10% 50HZ/60HZ,  AC 380V±10% 50HZ/60HZ, DC24V
Insulation resistance   100MΩ/500VDC 
Anti-pressure level   1500VAC 1Min
Protection level   IP67(It is no leakage in water about 20 meters deep)
Limited component   Power-driven: Fully open and close, limit switch.
  Manual: Mechanical stopper.
Protector   Overheat protector(self-recovery)
Installation position   Any direction from 0 to 360 degree
Electrical connection   M20*1.5 Waterproof cable connection, power wire, signal wire
Ambient Temp.   -30ºC--60ºC
 

2.Installation Diagram

Electric Actuator

3.Control Diagram
Electric Actuator

Model Circuit Model Circuit
S ON/OFF,no output signal CPT ON/OFF,output 4~20mA signal
MS ON/OFF,output passive contact signal PCU Regulation,output 4~20mA signal
PIU ON/OFF,output 0~1000Ω signal G ON/OFF,output passive contact signal
SP ON/OFF,middle position control H ON/OFF,output passive contact signal

 

Packing&Shipping
1.Packing: inner with bubble wrap,outer with cardboard box and wooden case.
2.Transportation:by sea,by air,by train.

Our Services
1.Professional consultation
2.24 hours response after sale.
3.One year warranty.
4.Safe packing for shipment.
5.Welcome sample order.

 

 We manufacture LPG Skid Mounted Station for filling LPG gas in cylinder of various capacities,there are various models available with storage tank capacity ranging from 5,000 liters to 50,000 liters and with the choice of single or many cylinder filling scales,the unit is provided with cylinder evacuation system,cylinder testing system.

LPG Skid Mounted Station

LPG Skid Mounted Stations, 10 CBM LPG Skid Stations, LPG Skid Plants, Skid LPG Filling Plants, Mobile LPG Skid Stations

Hubei Chusheng Vehicle Co., Ltd. , https://www.eetrucks.com